Abstract
Background: This study aimed to assess the accuracy of the standing leg-to-leg bioelectrical impedance
analyzer (LBIA) for estimating abdominal visceral fat with body mass index (BMI) scores ranging from
non-overweight to obese in elderly Chinese individuals.
Methods: The abdominal visceral fat area (VFA) at the lumbar level of L4-L5 was measured for 100 elderly
(age 68.5 ± 8.5 years) individuals using LBIA and computed tomography (CT) (respectively represented as
VFALBIA and VFACT). The VFA from LBIA were compared with those from CT under various BMI levels.
Results: The average BMI of the subjects was 24.3 ± 4.1 kg/m2 (58 non-overweight individuals had
BMIs < 25 kg/m2, and 42 overweight individuals had BMIs 25 kg/m2). The correlation coefficient (r) of
VFALBIA and VFACT was r ¼ 0.707 with a standard estimate of error (SEE) ¼ 21.96 cm2, and the limit of
agreement (LOA) was in the range of 67.46 to 58.48 cm2. The r value for non-overweight and overweight
was 0.707 (p < 0.001) and 0.356 (p < 0.001), SEE was 21.36 cm2 and 20.42 cm2 with LOA values
ranged between 68.40 to 46.00 cm2 and 61.79 to 71.19 cm2.
Conclusion: The LBIA results showed that each obese group all has large LOAwhen compared with the CT
reference values. The study suggests that the LBIA accuracy for estimating VFA is limited in the Chinese
elderly population.
analyzer (LBIA) for estimating abdominal visceral fat with body mass index (BMI) scores ranging from
non-overweight to obese in elderly Chinese individuals.
Methods: The abdominal visceral fat area (VFA) at the lumbar level of L4-L5 was measured for 100 elderly
(age 68.5 ± 8.5 years) individuals using LBIA and computed tomography (CT) (respectively represented as
VFALBIA and VFACT). The VFA from LBIA were compared with those from CT under various BMI levels.
Results: The average BMI of the subjects was 24.3 ± 4.1 kg/m2 (58 non-overweight individuals had
BMIs < 25 kg/m2, and 42 overweight individuals had BMIs 25 kg/m2). The correlation coefficient (r) of
VFALBIA and VFACT was r ¼ 0.707 with a standard estimate of error (SEE) ¼ 21.96 cm2, and the limit of
agreement (LOA) was in the range of 67.46 to 58.48 cm2. The r value for non-overweight and overweight
was 0.707 (p < 0.001) and 0.356 (p < 0.001), SEE was 21.36 cm2 and 20.42 cm2 with LOA values
ranged between 68.40 to 46.00 cm2 and 61.79 to 71.19 cm2.
Conclusion: The LBIA results showed that each obese group all has large LOAwhen compared with the CT
reference values. The study suggests that the LBIA accuracy for estimating VFA is limited in the Chinese
elderly population.
Subjects
Abdominal Obesity; Body Composition; Computed Tomography; Reliability
Publisher
Elsevier Taiwan LLC.
Type
article
File(s)
No Thumbnail Available
Name
index.html
Size
131 B
Format
HTML
Checksum
(MD5):b5ec35d30690ef2d67ea2a9d608e9a66
Loading...
Name
ssc01-201709-1.pdf
Size
547.1 KB
Format
Adobe PDF
Checksum
(MD5):e9f0f7dce778cd13667b32be283aa97b