Repository logo
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Organizations
    Statistics
  • English
  • 中文
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. 運動科學研究中心
  3. 期刊論文
  4. Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children
 
  • Details
Options

Validation of two portable bioelectrical impedance analyses for the assessment of body composition in school age children

Resource
PLoS ONE, Vol.12 ,NO.2, pp. e0171568
Date Issued
2018-06-05T12:17:09Z
Date
2017-02-03
DOI
10.1371/journal.pone.0171568
URI
https://ir.ntus.edu.tw/handle/987654321/68963
Abstract
Background
Bioelectrical impedance analysis (BIA) is a convenient and child-friendly method for longitudinal analysis of changes in body composition. However, most validation studies of BIA have been performed on adult Caucasians. The present cross-sectional study investigated the validity of two portable BIA devices, the Inbody 230 (BIA8MF) and the Tanita BC-418 (BIA8SF), in healthy Taiwanese children.
Methods
Children aged 7–12 years (72 boys and 78 girls) were recruited. Body composition was measured by the BIA8SF and the BIA8MF. Dual X-ray absorptiometry (DXA) was used as the reference method.
Results
There were strong linear correlations in body composition measurements between the BIA8SF and DXA and between the BIA8MF and DXA. Both BIAs underestimated fat mass (FM) and percentage body fat (%BF) relative to DXA in both genders The degree of agreement in lean body mass (LBM), FM, and %BF estimates was higher between BIA8MF and DXA than between BIA8SF and DXA. The Lin’s concordance correlation coefficient (ρc) for LBM8MF met the criteria of substantial to perfect agreement whereas the ρc for FM8MF met the criteria of fair to substantial agreement. Bland-Altman analysis showed a clinically acceptable agreement between LBM measures by BIA8MF and DXA. The limit of agreement in %BF estimation by BIA and DXA were wide and the errors were clinically important. For the estimation of ALM, BIA8SF and BIA8MF both provided poor accuracy.
Conclusions
For all children, LBM measures were precise and accurate using the BIA8MF whereas clinically significant errors occurred in FM and %BF estimates. Both BIAs underestimated FM and %BF in children. Thus, the body composition results obtained using the inbuilt equations of the BIA8SF and BIA8MF should be interpreted with caution, and high quality validation studies for specific subgroups of children are required prior to field research.
Publisher
PLoS ONE
Type
article
File(s)
No Thumbnail Available
Name

index.html

Size

136 B

Format

HTML

Checksum

(MD5):68d64cb0fd7675210e26e90383fa7be3

Loading...
Thumbnail Image
Name

ssc01-201702-1.pdf

Size

1.96 MB

Format

Adobe PDF

Checksum

(MD5):e3a29700703caf3d0c9c648e5d8eb230

Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Cookie settings
  • Privacy policy
  • End User Agreement
  • Send Feedback