Publication:
Evaluation of a Leg-to-Leg Bioimpedance Device in the Estimation of Abdominal Visceral Fat for the Elderly - Comparison with CT

cris.lastimport.scopus2026-02-23T16:03:25Z
dc.creatorLai, Cheng-Chyuan
dc.creatorLu, Hsueh-Kuan
dc.creatorChiang, Li-Ming
dc.creatorChiang, Jasson
dc.creatorHsieh, Kuen-Chang
dc.creatorLai, Chung-Liang
dc.date2017-09
dc.date.accessioned2021-11-03T07:47:24Z
dc.date.accessioned2025-07-28T14:29:17Z
dc.date.available2021-11-03T07:47:24Z
dc.date.issued2021-11-03T07:47:24Z
dc.description.abstractBackground: This study aimed to assess the accuracy of the standing leg-to-leg bioelectrical impedance analyzer (LBIA) for estimating abdominal visceral fat with body mass index (BMI) scores ranging from non-overweight to obese in elderly Chinese individuals. Methods: The abdominal visceral fat area (VFA) at the lumbar level of L4-L5 was measured for 100 elderly (age 68.5 +/- 8.5 years) individuals using LBIA and computed tomography (CT) (respectively represented as VFALBIA and VFACT). The VFA from LBIA were compared with those from CT under various BMI levels. Results: The average BMI of the subjects was 24.3 +/- 4.1 kg/m(2) (58 non-overweight individuals had BMIs < 25 kg/m(2), and 42 overweight individuals had BMIs >= 25 kg/m(2)). The correlation coefficient (r) of VFALBIA and VFACT was r = 0.707 with a standard estimate of error (SEE) = 21.96 cm(2), and the limit of agreement (LOA) was in the range of -67.46 to 58.48 cm(2). The r value for non-overweight and overweight was 0.707 (p < 0.001) and 0.356 (p < 0.001), SEE was 21.36 cm(2) and 20.42 cm(2) with LOA values ranged between -68.40 to 46.00 cm(2) and -61.79 to 71.19 cm(2). Conclusion: The LBIA results showed that each obese group all has large LOA when compared with the CT reference values. The study suggests that the LBIA accuracy for estimating VFA is limited in the Chinese elderly population. Copyright (C) 2017, Taiwan Society of Geriatric Emergency & Critical Care Medicine. Published by Elsevier Taiwan LLC. This is an open access article under the CC BY-NC-ND license.
dc.format.extent142 bytes
dc.format.mimetypetext/html
dc.identifier.doi10.1016/j.ijge.2016.03.013
dc.identifier.issn1873-9598
dc.identifier.urihttps://ir.ntus.edu.tw/handle/987654321/65122
dc.languageen_US
dc.publisherTaiwan: TAIWAN SOC GERIATRIC EMERGENCY & CRITICAL CARE MEDICINE-TSGE
dc.relationINTERNATIONAL JOURNAL OF GERONTOLOGY, 11(3), p.144-148
dc.subjectabdominal obesity
dc.subjectbody composition
dc.subjectcomputed tomography
dc.subjectreliability
dc.titleEvaluation of a Leg-to-Leg Bioimpedance Device in the Estimation of Abdominal Visceral Fat for the Elderly - Comparison with CT
dc.typearticle
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
index.html
Size:
142 B
Format:
Hypertext Markup Language
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
702 B
Format:
Plain Text
Description: