Publication:
Standing 8-Electrode Bioelectrical Impedance Analysis as an Alternative Method to Estimate Visceral Fat Area and Body Fat Mass in Athletes

cris.lastimport.scopus2026-03-07T16:02:10Z
dc.creatorLee, Ling-Chun
dc.creatorHsu, Pi-Shan
dc.creatorHsieh, Kuen-Chang
dc.creatorChen, Yu-Yawn
dc.creatorChu, Lee-Ping
dc.creatorLu, Hsueh-Kuan
dc.creatorChiu, Yen-Chen
dc.creatorLi, Lin
dc.creatorLai, Chung-Liang
dc.date2021
dc.date.accessioned2021-11-13T03:13:52Z
dc.date.accessioned2025-07-28T14:29:10Z
dc.date.available2021-11-13T03:13:52Z
dc.date.issued2021-11-13T03:13:52Z
dc.description.abstractPurpose: To investigate the potential of standing 8-electrode bioelectrical impedance analysis (BIA) for assessing visceral fat area (VFA) and body fat mass (BFM) in athletes. Materials and Methods: A total of 95 subjects (50 males and 45 females) were recruited. VFA and BFM measurements were obtained using three standing 8-electrode BIA devices, InBody230, InBody770, and IOI353. These acquired VFA and BFM were expressed as VFA(IOI353), VFA(InBody230), VFA(InBody770) V, BFMIOI353, BFMInBody230 and BFMInBody770, respectively. As reference measurement, the VFA acquired from computer tomography (CT) was expressed as VFA(CT), and the BFM measured by dual-energy X-ray absorptiometry (DXA) was denoted as BFMDXA. Results: The coefficient of determination (r(2)) in regression analysis between the measurements by VFA(IOI353), VFA(InBody230), VFA(InBody770) and VFA(CT) were 0.425, 0.492, and 0.473, respectively. Also, the limits of agreement (LOA) obtained from Bland-Altman analysis were -25.18 to 56.62, -29.74 to 62.44, and -32.96 to 71.93 cm(2). For BFM, r(2) in regression analysis between the measurements by BFMIOI353, BFMInBody230, BFMInBody770 and BMFDXA were 0.894, 0.950, and 0.955, respectively; LOA were -7.21 to 5.75, -4.70 to 4.05, and -5.48 to 3.05 kg, respectively. Conclusion: The results showed when assessing BFM, these instruments delivered comparable measurements, and the degree of agreement ranged from excellent to moderate compared with the reference method. However, when assessing VFA, the agreements were weak. Therefore, the application of standing 8-electrode BIA devices for assessing athletes' VFA still needs improvement.
dc.format.extent196 bytes
dc.format.mimetypetext/html
dc.identifier.doi10.2147/IJGM.S281418
dc.identifier.issn1178-7074
dc.identifier.urihttps://ir.ntus.edu.tw/handle/987654321/65092
dc.languageen_US
dc.publisherAUCKLAND, NEW ZEALAND: DOVE MEDICAL PRESS
dc.relationINTERNATIONAL JOURNAL OF GENERAL MEDICINE, 14, 539-548
dc.subjectbioelectrical impedance analysis
dc.subjectbody fat mass
dc.subjectvisceral fat area
dc.titleStanding 8-Electrode Bioelectrical Impedance Analysis as an Alternative Method to Estimate Visceral Fat Area and Body Fat Mass in Athletes
dc.typearticle
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
index.html
Size:
196 B
Format:
Hypertext Markup Language
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
702 B
Format:
Plain Text
Description: