Publication: 投手肩關節介入肌內效貼布後之肌電圖改變
| dc.contributor.advisor | 駱明瑤;陳勝凱 | |
| dc.contributor.advisor | Lou, Ming-Yao;Chen, Sheng-Kai | |
| dc.creator | 張世錫 | |
| dc.creator | Chang, Shih-hsi | |
| dc.date | 2010 | |
| dc.date.accessioned | 2017-02-27T06:37:10Z | |
| dc.date.accessioned | 2025-07-30T15:30:08Z | |
| dc.date.available | 2017-02-27T06:37:10Z | |
| dc.date.issued | 2017-02-27T06:37:10Z | |
| dc.description | 學位類別:碩士 | |
| dc.description | 校院名稱:國立台灣體育大學 | |
| dc.description | 系所名稱:體育研究所 | |
| dc.description | 學號:19601002 | |
| dc.description | 畢業學年度:98年 | |
| dc.description | 論文頁數:117頁 | |
| dc.description.abstract | 研究背景:肩關節在上肩投擲運動的作用佔28 %,其關節穩定度主要由肌群與軟組織調控。目的:探討棒球選手肌肉疲勞前後與肌內效貼紮後之最大球速與肌電圖改變。方法:6位大專乙組棒球選手先進行最大球速測試並收集最大自主等長收縮的肌電圖(肱二頭肌、前、中、後三角肌),再依序收集疲勞前、疲勞、肌內效貼紮後的五球最大球速的肌電圖與影像,以均方根與中位頻率分析肌電訊號改變。統計:重複量數單因子變異數分析(repeated measures ANOVA)比較三種狀況中肌電圖之差異,配對t檢定考驗疲勞與肌內效貼紮對疲勞前改變之差異。結果:肌內效貼紮後最大球速比疲勞後高,肱二頭肌(疲勞前後與肌內效貼紮後的平均數:18.40、28.72、18.57)、前與中三角肌(前:16.69、21.66、14.53,中:25.66、24.76、19.33)的均方根明顯比疲勞後低,並且此三條肌肉的中位頻率也比疲勞後高。結論:肌內效貼紮可降低運動單位同時活化並且有效增加運動單位的徵招,藉此幫助肌肉功能,以達到工作負荷的需求。肌肉疲勞後經過肌內效貼紮後球速小幅增加,顯示肌內效貼布可加快肌肉從疲勞的狀態下恢復。建議:未來研究可合併運動學並且增加肌電電極設置,使資料收集完備,教練、運動傷害防護員作為預防運動傷害之參考,幫助選手追求好表現。 | |
| dc.description.abstract | Background: Shoulder joint account for 28 % function of overhead exercise, and muscle tendon unit is the main source of stability in this joint. Purpose: Aim to investigate the effect of kinesio tape on post-fatigue muscle of shoulder joint. Methods: 6 college second level baseball players are to test the maximum pitching speed and recoded EMG of maximum voluntary contraction. After previous test, data were recorded by surface EMG from four different muscles in pre-fatigue, post-fatigue, and after kinesio taping. Statistics: Repeated measures analysis of variance was to test the different between pre-fatigue, fatigue, and after kinesio taping. Tukey’s HSD was enrolled in finding source of difference and paired t test was used to compare change amounts of fatigue vs. pre-fatigue and after kinesio taping vs. pre-fatigue. Results: RMS of biceps brachii (18.57 ± 4.82), anterior (14.53 ± 4.07), and middle deltoid (19.33 ± 3.32) after kinesio taping are lower then fatigue (biceps: 28.72 ± 5.18; anterior: 21.66 ± 5.64; middle: 24.76 ± 7.03). All of the muscles after kinesio taping (biceps: 87.35 ± 2.41; anterior: 90.51 ± 5.23; middle: 94.22 ± 6.34; posterior: 90.65 ± 5.74) had higher median frequency than in fatigue(biceps: 77.32 ± 4.12;anterior: 79.49 ± 5.14; middle: 83.06 ± 5.26; posterior: 78.26 ± 6.15). Conclusions: Kinesio taping could increase muscle recovery rate from fatigue by increase amounts of motor units recruited and improve sport performance. Suggestions: EMG had to be more powerful to explain how muscle works after analyzed with kinematics. Thus, there were more information about mechanism of pitching for coaches, pitchers, and athlete trainers. | |
| dc.description.tableofcontents | 目 次 第一章 緒論……………………………………………………………1 第一節 研究背景……………………………………………………1 第二節 研究動機與目的……………………………………………3 第三節 研究問題與假設……………………………………………3 第四節 研究範圍與限制……………………………………………4 第五節 名詞解釋……………………………………………………5 第二章 文獻探討………………………………………………………6 第一節 肩關節的解剖構造與本體感覺……………………………6 第二節 上肩運動與本體感覺………………………………………12 第三節 肌肉疲勞與本體感覺………………………………………14 第四節 貼紮對本體感覺與肌電圖的影響…………………………17 第五節 肌電圖之測量與分析………………………………………20 第三章 研究設計………………………………………………………23 第一節 研究對象……………………………………………………23 第二節 實驗設置與流程……………………………………………23 第三節 資料處理與分析……………………………………………31 第四章 結果……………………………………………………………34 第一節 基本資料與球速分析………………………………………35 第二節 肌電圖標準化均方根值的改變……………………………38 第三節 肌電圖未標準化均方根值的改變…………………………65 第四節 肌電圖中位頻率的改變……………………………………69 第五節 放球前後的肌電圖變化……………………………………83 第五章 討論……………………………………………………………85 第一節 肌電圖標準化均方根值的改變……………………………86 第二節 肌電圖中位頻率的改變……………………………………89 第三節 小結…………………………………………………………90 第六章 結論與建議……………………………………………………91 引用文獻…………………………………………………………………94 附錄……………………………………………………………………102 | |
| dc.format.extent | 2411816 bytes | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.uri | https://ir.ntus.edu.tw/handle/987654321/71008 | |
| dc.language | zh-TW | |
| dc.publisher | 體育研究所 | |
| dc.relation.isbasedon | Angela, R. T., Philip, M., Stephen, K., & Dominic I. (2008). Effect of the scapula reposition test on shoulder impingement symptoms and elevation strength in overhead athletes. Journal of Orthopaedic & Sports Physical Therapy, 38(1), 4-11. Arabadzhiev, T. I., Dimitrov, V. G., Dimitrova, N. A., & Dimitrov, G. V. (2010). Interpretation of EMG integral or RMS and estimates of "neuromuscular efficiency" can be misleading in fatigue contraction. Journal of Electromyography and Kinesiology, 20, 223-232. Armfield, D. R., Stickle, R. L., Robertson, D. D., Towers, J. D., & Debski, R. E. (2003). Biomechanical basis of common shoulder problems. Seminar in Musculoskeletal Radiology, 7(1), 1-18. Aydin, T., Yildiz, Y., Yanmis, İ., Yildiz, C., & Kalyon, T. A. (2001). Shoulder proprioception: a comparison between the shoulder joint in healthy and surgically repaired shoulders. Archives of Orthopaedic and Trauma Surgery, 121, 422-425. Barrack, R. L., Skinner, H. B., & Buckley SL. Proprioception in the anterior cruciate ligament deficient knee. The American Journal of Sports & Medicine, 17, 1-6. Bilis, M. (2000). Musculoskeletal assessment: Joint range of motion and manual muscle strength (2nd ed.). Philadelphia: Lippincott Williams & Wilkins. Bolgla, L. A., & Uhl, T. L. (2007). Reliability of electromyographic normalization methods for evaluating the hip musculature. Journal of Electromyography and Kinesiology, 17, 102-111. Bresch, J. P., & Nuber, G. (1995). Mechanoreceptors of the middle and inferior glenohumeral ligaments: histologic study of human cadaver shoulders. Journal of Shoulder & Elbow Surgery, 4, S63-4. Carpenter, J. E., Blasier, R. B., & Pellizzon, G. G. (1998). The effects of muscle fatigue on shoulder joint position sense. The American Journal of Sports Medicine, 26(2), 262-265. Chen, S. K., Simonian, P. T., Wickiewicz, T. L., Otis, J. C., & Warren, R. F. (1999). Radiographic evaluation of glenohumeral kinematics: a muscle fatigue model. Journal of Shoulder and Elbow Surgery, 8, 49-52. Constant, C. R., & Murley, A. H. (1987). A clinical method of functional assessment of the shoulder. Clinical Orthopaedics and Related Research, 214, 160-164. Dover, G. C., Kaminski, T. W., Meister, K., Powers, M. E., & Horodyski, M. (2003). Assessment of shoulder proprioception in the female softball athlete. The American Journal of Sports Medicine, 31(3), 431-437. Escamilla, R. F., & Andrews, J. R. (2009). Shoulder Muscle recruitment patterns and related biomechanics during upper extermity sports. Sports Medicine, 39(7), 569-590. Escamilla, R. F., Barrentine, S. W., Fleisig, M. S., Zheng, N., Takada, Y., Kingsley, D. et al. (2007). Pitching biomechanics as a pitcher approaches muscular fatigue during a simulated baseball game. The American Journal of Sports Medicine, 35(1), 23-33. Freeman, M. A., Dean, M. R., & Hoffman, W. F. (1965). The etiology and prevention of functional instability of the foot. The Journal of Bone & Joint Surgery. British volume, 47, 678-685. Fuglevand, A. J., Zackowski, K. M., Huey, K. A., & Enoka, R. M. (1993). Impairment of neuromuscular propagation during human fatiguing contractions at submaximal forces. Journal of Physiology, 460, 549-572. Glencross, D., & Thorton, E. (1981). Position sense following joint injury. The Journal of Sports Medicine and Physical Fitness, 21, 21-23. Guanche, C., Knatt, T., Solomonow, M., Lu, Y., & Baratta, R. (1995). The synergistic action of the capsule and the shoulder muscles. The American Journal of Sports & Medicine, 23(3), 301-306. Halder, A.M., Kuhl, S. G., Zobitz, M.E., Larson, D., & An, K.N. (2001). Effects of the glenoid labrum and glenohumeral abduction on stability of the shoulder joint through concavity-compression: an in vitro study. The Journal of Bone and Joint Surgery. American volume, 83, 1062–1069. Hsu, Y. H., Chen, W. Y., Lin, H. C., Wang, W. T., & Shih, Y. F. (2009). The effects of taping on scapular kinematics and muscle performance in baseball players with shoulder impingement syndrome. Journal of Electromyography and Kinesiology, 19(6), 1092-1099. Illyé, Á., & Kiss, R. M. (2005). Shoulder muscle activity during pushing, pulling, elevation and overhead throw. Journal of Electromyography and Kinesiology, 15, 282-289. Keenan, K. G., Farina, D., Maluf, K. S., Merletti, R., & Enoka1, R. M. (2005). Influence of amplitude cancellation on the simulated surface electromyogram. Journal of Applied Physiology, 98, 120–131. Lattanzio, P. J., Petrella, R. J., Sproule, J. R., & Fowler, P. J. (1997). Effects of fatigue on knee proprioception. Clinical Journal of Sport Medicine, 7, 22-27. Lazarus, M. D., Sidles, J. A., Harryman II, D. T., & Matsen III, F. A. (1996). Effect of a chondral-labral defect on glenoid concavity and glenohumeral stability. Acadaveric model. The Journal of Bone & Joint Surgery. American volume, 78, 94-102. Lee, H. M., Liau, J. J., Cheng, C. K., Tan, C. M., & Shih, J. T. (2003). Evaluation of shoulder proprioception following muscle fatigue. Clinical Biomechanics, 18, 843–847. Lephart, S. M., Pincivero, D. M., Giraldo, J. L., & Fu, F. H. (1997). The role of proprioception in the management and rehabilitation of athletic injuries. The American Journal of Sports Medicine, 25(1), 130-137. Lou, M. Y., & Chen, C. Y.(2003). Effects of the application of kinesio-tape and traditional-tape on motor perception. Poster session presented at the International Society of Biomechanics XIXth congress, Otago university, Dunedin, New Zeland. Lou, M. Y. (2002). The effect of kinesio-tape and traditional tape on knee joint proprioceptor and soccer skill.[abstract] The 44th ICHPER.SD world congress in Taipei program & abstracts(p. 26-27). Taipei, Taiwan: ICHPER.SD. Mario, C., Vladimir, M., Stanko, T., & Saša, O. (2009). Surface EMG based muscle fatigue evaluation in biomechanics. Clinical biomechanics, 24, 327-340. Moore, K. L., & Dalley, A. F. (1999) Clinically oriented anatomy(4th ed.)(pp. 665-719). US: Lippincott Wiliams & Wilkins. Murray, H. M., & Husk, L. J. (2001). Effects of Kinesio taping on proprioception in the ankle. Journal of Orthopedic and Sports Physical Therapy, 31(1), A-37. Murray, H. M. (2000). Kinesio taping, muscle strength and rom after ACL repair. Journal of Orthopedic & Sports Physical Therapy, 30(1), A-14. Myers, J. B., Laudner, K. G.,. Pasquale, M. R., Bradley, J. P., & Lephart, S. M. (2005). Scapular position and orientation in throwing athletes. The American Journal of Sports Medicine, 33(2), 263-271. Roger, M. E. (1995). Mechanisms of muscle fatigue: central factors and task dependency. Journal of Electromyography and Kinesiology, 5, 141-149. Safran, M. R., Borsa, P. A., Lephart, S. M., Fu, F. H., & Warner, J. J. (2001). Shoulder proprioception in baseball pitchers. Journal of Shoulder and Elbow Surgery, 10, 438-444. Selkowitz, D. M., Chaney, C., Stuckey, S. J., & Vlad, G. (2007). The effects of scapular taping on the surface electromyographic signal amplitude of shoulder girdle muscles during upper extremity elevation in individuals with suspected shoulder impingement syndrome. Journal of Orthopaedic & Sports Physical Therapy, 37(11), 694-702. Stefan, K., & Björn, G. (2001). Mean frequency and signal amplitude of the surface EMG of the quadriceps muscles increase with increasing torque — a study using the continuous wavelet transform. Journal of Electromyography and Kinesiology, 11, 131-140. Teyhen, D. S., Miller, J. M., Middag, T. R., & Kane, E. J. (2008). Rotator cuff fatigue and glenogumeral kinematics in participants without shoulder dysfunction. Journal of Athletic Training, 43(4), 352-358. Tibone, J. E., Fechter, J., & Kao, J. T. (1997). Evaluation of a Proprioception pathway in patients with stable and unstable shoulders with somatosensory cortical evoked potentials. Journal of Shoulder and Elbow Surgery, 6, 440-443. Tripp, B. L., Uhl, T. M., Mattacola, C. G., Srinivasan, C., & Shapiro R. (2006). A comparison of individual joint contributions to multijoint position reproduction acuity in overhead-throwing athletes. Clinical Biomechanics, 21, 466-473. Tripp, B. L., Yochem, E. M., & Uhl, T. L. (2007). Functional fatigue and upper extremity sensorimotor system acuity in baseball athletes. Journal of Athletic Training, 42(1), 90-98. Ulkar, B., Kunduracioglu, B., Çetin, C., & Güner, R. S. (2004). Effect of positioning and bracing on passive position sense of shoulder joint. British Journal of Sports and Medicine, 38, 549-552. Vangsness, C. T., Ennis, M., Taylor, J. G., & Atkinson, R. (1995). Neural anatomy of the glenohumeral ligaments, labrum and subacromial bursa. Arthroscopy, 11, 180-4. Voight, M. L., Hardin, J. A., Blackburn, T. A., Tippett, S., & Canner, G. C. (1996). The effects of muscle fatigue on and the relationship of arm dominance to shoulder proprioception. Journal of Orthopaedic & Sports Physical Therapy, 23(6), 348-352. Wilk, K. E., Meister, K., & Andrews, J. R. (2002). Current concepts in the rehabilitation of the overhead throwing athlete. The American Journal of Sports Medicine, 30(1), 136-151 William, E. P. (2003). Arnheim’s principles of athletic training (11th ed.)(pp. 696-700). New York: McGraw – Hill. 王百川(2003)。運動貼紮法。臺北縣:科正出版社。 林清山(2004)。心理與教育統計學。臺北市:東華書局。 駱明瑤(1999)。機能貼布使用與方法與原理。臺中市:華格那出版社。 駱明瑤(2004)。機能貼布使用與方法與原理-運動傷害實用篇Ⅱ。臺中市:華格那出版社。 | |
| dc.subject | 上肩投擲;中位頻率;均方根;運動傷害預防 | |
| dc.subject | overhead exercise;proprioception;kinesio tape;joint position reproduction;active multijoint position reproduction | |
| dc.title | 投手肩關節介入肌內效貼布後之肌電圖改變 | |
| dc.title | CHANGE IN ELECTROMYOGRAPHY OF SHOULDER JOINT AFTER KINESIO TAPING IN PITCHERS | |
| dc.type | thesis | |
| dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1